• United States
IBM®
  • Site map

  • z/VM
  • News
  • About z/VM
  • Events calendar
  • Products and features
  • Downloads
  • Technical resources
  • Library
  • How to buy
  • Install
  • Service
  • Support
  • Education
  • z/VM Change logs
  • Site map
  • Site search
  • Notify me
  • Contact z/VM
  • Overview
  • Upgrade
  • SDO
  • Resources
  • News
  • Tips

z/VM Installation News

Updated: 24 July 2025 (see also z/VM Site News)

For your awareness:

  • 7.4 Installation upgrade problem UPGCRC01 mitigation utility (July 2025)

    When upgrading to z/VM 7.4, multiple errors can occur, some of which are dependent upon the configuration of the system being upgraded. Errors that might be produced when the INSTUPGR STAGE2 (COMMIT command is run are:

    • Message DMSABE141TE produced after DDR processing of the MAINT 190 disk:
        ...
        Now processing line nnn of mmm
        ...
        z/VM DASD DUMP/RESTORE PROGRAM
        COPYING   MNT190
        COPYING DATA  11/25/24 AT 11.14.23  GMT FROM MNT190 TO MNT190
        INPUT CYLINDER EXTENTS      OUTPUT CYLINDER EXTENTS
              START       STOP         START        STOP
                  0        213             0         213
        END OF COPY
        END OF JOB
        DMSABE141T Protection exception occurred at xxxxxxxx in routine EXECDROP
      
    • Message VMFBLD1836E produced when command VMFINS BUILD PPF SERVP2P VMSES (SERVICED LINK is invoked by INSTUPGR:

      Console messages:

        ...
        IUG2EX8508I Record: SESCMD FINSBLD VMFINS BUILD PPF SERVP2P VMSES (SERVICED LINK
        IUG2EX8342E Command 'VMFINS BUILD PPF SERVP2P VMSES (SERVICED LINK' failed with RC=8
        IUGUPG8342E Command 'INSTS2EX 740' failed with RC=100
        IUGUPG8376E INSTUPGR STAGE2 ( COMMIT ended in error.
        ...
      

      VMFINS command ($VMFINS) $MSGLOG messages:

        ...
        VMFINB2603I Building product :PPF SERVP2P VMSES :PRODID 7VMSES40%VMSES
        ...
        VMFBLD2760I VMFBLD processing started
        VMFBLD1836E This program requires BUILD8 5E6 to be accessed as R/W because it is a target of build lists
        ...
      
    • Messages DMSPCL386E and VMFSRV1965E (among others) produced when command SERVICE CP BLDNUC is invoked by INSTUPGR, or, when a SERVICE command is used to install new service after having completed a z/VM 7.4 system upgrade:

      Console messages:

        ...
        IUG2EX8508I Record: SESCMD BLDNUC SERVICE CP BLDNUC
        IUG2EX8342E Command 'SERVICE CP BLDNUC' failed with RC=100
        ...
      

      SERVICE command ($VMFSRV) $MSGLOG messages:

        ...
        ST:VMFSRV2760I SERVICE processing completed successfully for CP BUILD
        ...
        CK:VMFSRV1233I The following products have been serviced.
        CK:VMFSRV1233I CP
        ST:VMFUTL2767I Reading VMFINS DEFAULTS B for additional options
        ST:VMFBMP2760I VMFBTMAP processing started
        ST:VMFBMP2760I VMFBTMAP processing started for
        SV:DMSPCL386E Missing operand(s)
        SV:VMFSET2760E VMFSETUP processing completed unsuccessfully (RC=24)
        ...
      

    To avoid these errors during the upgrade process, a circumventive utility exec (UPGCRC01, currently) is available and recommended for use as part of the upgrade process. To be effective, this utility must be acquired and in place before the INSTUPGR STAGE2 (COMMIT command is first used. In addition, modifications to the upgrade process $STAGE2$ $TABLE$ file are required so this utility is invoked accordingly, at specific points, when the INSTUPGR STAGE2 (COMMIT command is run.

    For details, consult the UPGCRC01 Utility setup and usage page.

    If the UPGCRC01 has not been used, and one of the aforementioned errors has been encountered, consult the z/VM 7.4 Upgrade problem manual fix information page for actions that can be taken to mitigate an existing such problem.

  • IBM Shopz order for z/VM 7.4 has install media under additional publications and incorrect file type for some files. (September 2024)

    Orders for z/VM 7.4 have the installation media files in the section marked as "Additional Publications" in IBM Shopz.

  • Applying RSU or other PTF service on 730 Upgraded SSI member system (February 2024)

    As noted in the z/VM 730 Installation Guide, it is possible to apply service to a first-upgraded, SSI member 730 system in an SSI cluster, before any other member systems are upgraded. However, when this is done, specific actions can be required for certain z/VM components that have been updated with the applied RSU or PTF service. The components to which this consideration applies are: DirMaint, ICKDSF and (possibly) Language Environment (LE)

    If you are planning, or actively working on, SSI cluster 730 system upgrades, review and make use of this "Instllation Tips" topic: Post-Upgrade RSU Installation

Footer links

  • Contact
  • Privacy
  • Terms of use
  • Accessibility