About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
SHUBK | Back to Index page |
Prolog Control Block Contents SHUBK DSECT Storage Layout Cross Reference (Contains links to field and bit definitions) |
|
SHUBK Control Block Content | Top of page |
|
SHUBK Storage Layout | Top of page |
*** SHUBK - SHUtdown Control Block * * +-------------------------------------------------------+ * 0 | SHUDATE | * | +-----------------------------------------+ * | | SHUTIME- | * +-------------+-----------------------------------------+ * 10 | -(00A) | SHUUSER- | * +-------------+-----------------------------------------+ * 18 | -(012) |/////////////////////////////////////////| * +-------------+-----------------------------------------+ * 20 | SHUTOD | * +---------------------------+---------------------------+ * 28 | SHUSEC |///////////////////////////| * +---------------------------+---------------------------+ * 30 * *** SHUBK - SHUtdown Control Block |
SHUBK Cross Reference | Top of page |
Symbol Dspl Value -------------- ---- ----- SHUBSIZE 002C 00000030 SHUDATE 0000 SHUSEC 0028 SHUSIZE 002C 00000006 SHUTIME 000A SHUTOD 0020 SHUUSER 0012 |
Copyright IBM Corporation, 1990, 2016