Programming Interface Information:
This page documents intended Programming Interfaces that allow the customer to write programs to obtain the services of z/VM. |
WUERROR
Control Block Contents
WUERROR DSECT
Cross Reference (Contains links to field and bit definitions)
WUERROR Prolog
Name : WUERROR Description: Workunit Extended Error Information DSECT : WUERROR Function : This macro maps the control data needed to provide Extended Error Information to the caller of CMS Program Functions.
WUERROR Control Block Content
WUERROR DSECT
Hex Dec Type/Val Lng Label (dup) Comments ---- ---- --------- ---- -------------- -------- 0000 0 Structure WUERROR Workunit Extended Error Information 0000 0 Signed 4 WUELEN length of WUAREA area 0004 4 Signed 8 WUECTRS (0) allows zeroing of counters 0004 4 Signed 4 WUERTNED number of FPERRORs returned 0008 8 Signed 4 WUETOTAL total number of FPERRORs 0000000C WUERRLEN *-WUERROR length of WUERROR prefix 00000002 WUEDBSZ ((WUERRLEN+7)/8) size of WUERROR prefix in doublewords 0000000C WUEAREA * area to put FPERRORs
WUERROR Storage Layout
*** WUERROR - Workunit Extended Error Information * * +---------------------------+---------------------------+ * 0 | WUELEN | WUERTNED | * +---------------------------+---------------------------+ * 8 | WUETOTAL | C * +---------------------------+ * *** WUERROR - Workunit Extended Error Information
WUERROR Cross Reference
Symbol Dspl Value -------------- ---- ----- WUEAREA 0008 0000000C WUECTRS 0004 WUEDBSZ 0008 00000002 WUELEN 0000 WUERRLEN 0008 0000000C WUERTNED 0004 WUETOTAL 0008
Last updated on 1 May 2002 at 14:10:40 EDT.