Programming Interface Information: This page documents intended Programming
Interfaces that allow the customer to write programs to obtain the services of VM/ESA.

CCED

Prolog  

Control Block Contents  

CCED DSECT

Storage Layout  

Cross Reference (Contains links to field and bit definitions)  

CCED Prolog

 NAME       : CCED
 DESCRIPTION: APPC/VM CONNECTION COMPLETE EXTENDED DATA BLOCK
 DSECT      : CCED
 FUNCTION   : TO PASS INFORMATION BETWEEN IUCV ENTRY POINTS.
 LOCATED BY : PDESADDR WHEN PDECCED IS SET IN THE PDEAPPF4 FIELD
 CREATED BY : HCPIUBAC
 DELETED BY : HCPIUMRF

 

CCED Control Block Content


CCED DSECT

Hex Dec Type/Val Lng Label (dup) Comments ---- ---- --------- ---- -------------- -------- 0000 0 Structure CCED APPC/VM CONNECTION COMPLETE EXTENDED DATA BLOCK 0000 0 Signed 2 CCEDTOTL EXTENDED DATA LENGTH 0002 2 Signed 2 CCEDFIXL LENGTH OF FIXED LENGTH FIELDS 0004 4 Signed 4 * RESERVED 0008 8 Bitstring 1 CCEDSIIL C*1 SESSION INSTANCE IDENTIFIER LEN 0009 9 Bitstring 1 CCEDCVCL C*2 CONVERSATION CORRELATOR LENGTH 000A 10 Bitstring 1 CCEDLFQL C*3 LOCAL FULLY QUALIFIED LU NAME LEN 000B 11 Bitstring 1 CCEDRFQL C*4 REMOTE FULLY QUALIF LU NAME LEN 000C 12 Signed 4 * RESERVED 0010 16 Bitstring 8 CCEDSII SESSION INSTANCE IDENTIFIER 0018 24 Bitstring 8 CCEDCVC CONVERSATION CORRELATOR 0020 32 Character 17 CCEDLFQN LOCAL FULLY QUALIFIED LU NAME 0031 49 Character 17 CCEDRFQN REMOTE FULLY QUALIFIED LU NAME 0042 66 Character 6 * RESERVED 0048 72 Character 8 CCEDUSER CONVERSATION ACCESS USERID THE FOLLOWING VALUE IS THE MINIMUM VALID SIZE OF THE CCED. ANY NEW FIELDS ADDED AFTER CCEDUSER SHOULD BE ADDED BETWEEN THE CCEDMINL AND CCEDFIX DEFINITIONS TO MAINTAIN THE MINIMUM SIZE. 00000050 CCEDMINL *-CCED MINIMUM VALID CCED SIZE 00000048 CCEDFIX *-CCEDSIIL FIXED FIELDS LENGTH 00000050 CCEDTOT *-CCED TOTAL LENGTH OF CCED 0000000A CCEDDBSZ (*-CCED+7)/8 DOUBLEWORD SIZE OF CCED

 

CCED Storage Layout

*** CCED - APPC/VM CONNECTION COMPLETE EXTENDED DATA BLOCK
*
*     +-------------+-------------+---------------------------+
*   0 |  CCEDTOTL   |  CCEDFIXL   |///////////////////////////|
*     +------+------+------+------+---------------------------+
*   8 |:DSIIL|:DCVCL|:DLFQL|:DRFQL|///////////////////////////|
*     +------+------+------+------+---------------------------+
*  10 |                       CCEDSII                         |
*     +-------------------------------------------------------+
*  18 |                       CCEDCVC                         |
*     +-------------------------------------------------------+
*  20 |                                                       |
*     =                       CCEDLFQN                        =
*     |      +------------------------------------------------+
*  30 |      |                                                |
*     +------+                                                |
*     |                       CCEDRFQN                        |
*     |             +-----------------------------------------+
*  40 |             |/////////////////////////////////////////|
*     +-------------+-----------------------------------------+
*  48 |                       CCEDUSER                        |
*     +-------------------------------------------------------+
*  50
*
*** CCED - APPC/VM CONNECTION COMPLETE EXTENDED DATA BLOCK

 

CCED Cross Reference

(contains links to field and bit definitions)
Symbol         Dspl Value
-------------- ---- -----

CCEDCVC 0018

CCEDCVCL 0009

CCEDDBSZ 0048 0000000A

CCEDFIX 0048 00000048

CCEDFIXL 0002

CCEDLFQL 000A

CCEDLFQN 0020

CCEDMINL 0048 00000050

CCEDRFQL 000B

CCEDRFQN 0031

CCEDSII 0010

CCEDSIIL 0008

CCEDTOT 0048 00000050

CCEDTOTL 0000

CCEDUSER 0048


This information is based on VM/ESA 2.4.0.
Last updated on 3 Aug 1999 at 11:35:41 EDT.
Copyright IBM Corporation, 1990, 1999